Hi,

Port 502 is assigned to Modbus, so that's what slaves should use by default.

Cheers,


Peter.

On 29/02/2012 9:40 PM, Mark Wendt wrote:
> On 02/28/2012 05:21 PM, Kirk Wallace wrote:
>> ... snip
>>
>> I think I know a little more now. I was able to bring up
>> "loadusr classicladder --modslave" (I didn't know the rt component had
>> to be loaded too). My netstat returned the same result above with
>> "0.0.0.0:9502". I then did a ifconfig to find my network computer's
>> addresses with 192.168.1.10 (eth0) and 127.0.0.0 (localhost) being
>> listed. I nmap both addresses and found port 9502 open on both, so it
>> seems by default, "--modslave" will listen on all addresses (two in this
>> case), with "all or any addresses" being called out as "0.0.0.0".
>> http://en.wikipedia.org/wiki/0.0.0.0
>>
>> If I use "loadusr classicladder --modslave --modbus_port=1502" netstat
>> sees port 1502 as listening, nmap doesn't see it whereas it did see 9502
>> previously. My guess is that as any ports above 1000 have lighter
>> restrictions, maybe ports above a higher value are handled differently
>> too, so 1502 doesn't show where 9502 does. I guess I have more work to
>> do.
>>
>> I haven't tried connecting to the LinuxCNC slave with a master yet.
>>
> Actually, ports 1024 and below are considered "privileged" ports.  Any
> ports above that are considered "non-privileged" ports and are all
> treated the same.  Do a 'netstat -a | grep 1502' and see if the 1502
> port shows up.
>
> Mark
>
>
> ------------------------------------------------------------------------------
> Virtualization&  Cloud Management Using Capacity Planning
> Cloud computing makes use of virtualization - but cloud computing
> also focuses on allowing computing to be delivered as a service.
> http://www.accelacomm.com/jaw/sfnl/114/51521223/
> _______________________________________________
> Emc-users mailing list
> Emc-users@lists.sourceforge.net
> https://lists.sourceforge.net/lists/listinfo/emc-users
>

-- 
-----------------------------------------------------------------------------
eStore: http://www.homanndesigns.com/store
Web   : http://www.homanndesigns.com     ModIO     - Modbus Interface Unit
email : pe...@homanndesigns.com          DigiSpeed - Isolated 10Vdc I/F
Phone : +61 421 601 665                  TurboTaig - Taig Mill Upgrade board

------------------------------------------------------------------------------
Virtualization & Cloud Management Using Capacity Planning
Cloud computing makes use of virtualization - but cloud computing 
also focuses on allowing computing to be delivered as a service.
http://www.accelacomm.com/jaw/sfnl/114/51521223/
_______________________________________________
Emc-users mailing list
Emc-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/emc-users

Reply via email to