Hello,

Just wondering if someone might know why LinuxCNC interprets the G04
dwell command parameter as seconds instead of milliseconds?
I'm fairly certain most other machines (ie Fanuc and others) interpret
the P value as milliseconds.
For example, the command:

G04 P3000

is interpreted by most machines as stop the tool for 3000 milliseconds
(3 seconds). But LinuxCNC interprets this as 3000 seconds.

Also, I think the G04 command should take X or P (or possibly U),
where the X value is normally in seconds and the P value is normally
milliseconds. LinuxCNC does not allow X values and will throw an error
if it encounters one.

If anyone can clear this up I would be grateful. I'm writing an
extension for Inkscape that generates G code and I'd like to make sure
that its output is nominally correct.

thanks,
- Claude


P.S. I'm using LinuxCNC to control an old Fletcher F6100 CNC mat
cutter that has a tangential knife (a fourth axis that rotates about
the Z axis that is always tangent to the direction of travel along the
X and Y axes)

------------------------------------------------------------------------------