On 11 July 2012 12:22, Gabriel Willen <gabewil...@gmail.com> wrote:
> I would think most industrial vfd's would work in conjunction with a mesa
> card that has +- 10V.

I think that Fanuc motors are AC synchronous (brushless permanent
magnet) so need a closed-loop drive.

The LinuxCNC "bldc" component understands the Fanuc "red cap"
commutation scheme, though, and can convert it to suit drives with a
different feedback requirement (synthetic Hall signals, for example)

-- 
atp