That is how I am doing it now, but I am using it in a production setting and 
would like to speed things up.  If that is the case, I could go into the 
scanner setup and put a delay between 'o' and the filename.

-----Original Message----- 
From: sam sokolik
Sent: Wednesday, September 19, 2012 7:56 AM
To: Enhanced Machine Controller (EMC)
Subject: Re: [Emc-users] Bar code error

I would guess that the open dialog box is not opening quick enough so
you loose some of the characters...  My thought would be to have to O as
a separate barcode on the machine.  Scan O then scan the part name.
(still quicker than typing)

On 9/19/2012 7:40 AM, Dave wrote:
> I have created bar codes (Code 128 Auto font) consisting of CAM filenames 
> with the hope of scanning these bar codes to speed up the process of 
> opening a program file.  I have added ‘o’ to the front end of the bar code 
> which will bring up the open dialogue box.  I have been unsuccessful in 
> getting this to work properly.  If I scan a barcode made from ‘o’ 
> separately, it will bring up the open dialogue box, then if I scan a 
> barcode consisting of just the filename, it will populate the filename 
> area in the dialogue box and load the program perfectly.  If I combine the 
> 2 operations in one barcode, I will get a “cannot find file” error because 
> it is dropping characters from the filename.
>
> Also, sometimes, I have noticed that the jog increment dropdown will 
> change from “continuous” to “.1” and actually jog the selected axis.
>
> I am using USB Honeywell hand held scanners. I have talked with Honeywell 
> support and told them of what is going on and they contend that my issues 
> are coming from the Linux EMC2 software compatibility because when I scan 
> my barcodes to Gedit, they produce the correct characters and carriage 
> return that I created them with.
>
> I have been told that this maybe happening because “the real-time kernal 
> which gives absolute priority to the motor control thread is interrupting 
> the “fake keyboard” input of the bar code reader”.  This is happening on 2 
> separate machines.
>
> Any ideas are welcomed.  Thanks!
> ------------------------------------------------------------------------------
> Live Security Virtual Conference
> Exclusive live event will cover all the ways today's security and
> threat landscape has changed and how IT managers can respond. Discussions
> will include endpoint security, mobile security and the latest in malware
> threats. http://www.accelacomm.com/jaw/sfrnl04242012/114/50122263/
> _______________________________________________
> Emc-users mailing list
> [email protected]
> https://lists.sourceforge.net/lists/listinfo/emc-users


------------------------------------------------------------------------------
Live Security Virtual Conference
Exclusive live event will cover all the ways today's security and
threat landscape has changed and how IT managers can respond. Discussions
will include endpoint security, mobile security and the latest in malware
threats. http://www.accelacomm.com/jaw/sfrnl04242012/114/50122263/
_______________________________________________
Emc-users mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/emc-users 


------------------------------------------------------------------------------
Live Security Virtual Conference
Exclusive live event will cover all the ways today's security and 
threat landscape has changed and how IT managers can respond. Discussions 
will include endpoint security, mobile security and the latest in malware 
threats. http://www.accelacomm.com/jaw/sfrnl04242012/114/50122263/
_______________________________________________
Emc-users mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/emc-users

Reply via email to