Quoth John Thornton.....
>The manuals are quite large, well not as large as they used to be so I 
>assume you missed this important section on HAL. In particular look at 
>the diagram in the net section 1.4.
>
>http://linuxcnc.org/docs/html/hal/basic_hal.html

You mean:

        "An OUT pin can be connected only if there are no other OUT or IO pins 
on
        the signal"

I most certainly read it....  understood is obviously another matter :-(
halui.jog.0.minus is an OUT pin then (I kind of thought it was an IN).

Anyway, that'll be a No.  One has to use or2.

Ta.
-- 
 Regards,
     Russell
 --------------------------------------------------------------------
| Russell Brown          | MAIL: [email protected] PHONE: 01780 471800 |
| Lady Lodge Systems     | WWW Work: http://www.lls.com              |
| Peterborough, England  | WWW Play: http://www.ruffle.me.uk         |
 --------------------------------------------------------------------

------------------------------------------------------------------------------