Thank you Sebastion,

This is for my new to me EMCO compact 5 cnc lathe retrofit.

I use a lot of "o" word loops in my programs.

When debugging if I get more than four messages ,they start to scroll
over my tool changer information.

So I thought if I could clear the messages just before I sent a new one
they wouldn't scroll ,making a cleaner display.

I will study what you suggest and see what I can come up with.

On 01/30/2014 01:51 PM, Sebastian Kuzminsky wrote:
> On 1/30/14 08:50 , Jim Wilkin wrote:
>> I would like to make a gcode Say G133 or M64 to perform the key stroke
>> ctl+space to clear the MSG and DBUG messages.
>>
>> I'm unable to find a "pin" to do this.
>>
>> Perhaps it has all ready been done?
>>
>> Any suggestions would be appreciated.
> 
> I think there's currently no easy way to do this, but it looks like it'd 
> be pretty straight forward to implement.
> 
> But i must ask, what is the use case for this?  What problem are you 
> trying to solve by clearing gui messages from gcode?
> 
> 
> If you want to implement this, i'd suggest:
> 
> * add a new command-line argument to axis-remote to send a new message 
> to axis,
> 
> * add the matching handler for that message in axis' TclCommands.remote()
> 
> * the handler would call Notifications.clear(), just like Ctrl-Space does
> 
> 
> Then you can add a custom M-code script to call "axis-remote 
> --clear-messages".
> 
> 

------------------------------------------------------------------------------
WatchGuard Dimension instantly turns raw network data into actionable 
security intelligence. It gives you real-time visual feedback on key
security issues and trends.  Skip the complicated setup - simply import
a virtual appliance and go from zero to informed in seconds.
http://pubads.g.doubleclick.net/gampad/clk?id=123612991&iu=/4140/ostg.clktrk
_______________________________________________
Emc-users mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/emc-users

Reply via email to