On 12/06/2014 08:55 PM, Jeremy Jones wrote:
> I had this working fine. Changed some stuff around today but nothing
> related to my limits. Now every time I home it searches, backs off and
> finds the limit but then it shuts down because I'm on a limit switch.
> Thoughts?
>
>
In the [AXIS_x] sections of your .ini file, you probably now 
have :
HOME_IGNORE_LIMITS =             NO

or, possibly no setting of this parameter.  Set it to YES, 
and it
will ignore the limit switch during a home operation.  If you
home via a limit switch, then you MUST have a
HOME_OFFSET = xx that gets it off the home switch during the
home operation.

Jon

------------------------------------------------------------------------------