On Thursday 08 October 2015 13:17:45 Gene Heskett wrote: > On Thursday 08 October 2015 11:41:57 andy pugh wrote: > > On 8 October 2015 at 15:32, Gene Heskett <[email protected]> wrote: > > > It looks like if I want to control a relay to run a vacuum to suck > > > up the wood dust, and I only want it to run when commanded, I will > > > have to use a charge_pump to get around the 5i25 that sets > > > everything high when linuxcnc is shut down. > > > > Why not wire with the 5i25 on the low side of the relay? > > Relay is not spdt, spst is all. > > > Cheers, Gene Heskett
To reduce the suspense, its working. Milliseconds response to turn it on, and about 2/3rds of a second to turn it off. Thats more than good enough for the girls I go with. ;-) But my other comment re achieving independent control from gcode still stands. I do have independent control from mousing the axis check boxes, but in gcode, an M9 turns them both off. Not an ideal thing IMO. I'll go read up on remapping & see if I can get my head around it. Cheers, Gene Heskett -- "There are four boxes to be used in defense of liberty: soap, ballot, jury, and ammo. Please use in that order." -Ed Howdershelt (Author) Genes Web page <http://geneslinuxbox.net:6309/gene> ------------------------------------------------------------------------------ _______________________________________________ Emc-users mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/emc-users