How would you explain that when parallel port transfers data 8 bytes at 
a time and I get errors only in one bit through 3 bytes at least?

02/02/2016 08:49 PM, Peter C. Wallace rašė:

> Sounds like errors in the EPP connection. I would try shortening the
> EPP cable to the minimum length (If you are using a flat cable) or
> if you need a longer cable, use a IEEE-1284 compatible cable
> and a very short flat cable adapter to the 7I43s header. Might also be a
> marginal EPP port on the Motherboard.
>
>
> Peter Wallace
> Mesa Electronics


------------------------------------------------------------------------------