On Fri, 2016-04-29 at 21:45 +0000, Ralph Stirling wrote:
> I wrote a small program that I ran on an old Linux
> PC to transfer files to a Mori Seiki lathe with Fanuc 0-iTC
> and to a Haas TM-1.  It waited on the handshake
> signal from the machine serial port, and would then
> fetch a single file from a network file system drive
> (either moricode.txt or haascode.txt according to the
> machine).  Users of the machines would copy their
> G-code file to the network drive as moricode.txt or
> haascode.txt, then walk over to the machine and
> punch the button sequence to read a file over the
> serial port.  Everything else was handled by the programs
> on the PC (which was headless).  I'll likely set this
> up on a BBB or RPi at some point.
> 
> I can dig up program source for anybody that wants
> it as a starting point.
> 
I'd be interested in that code, I did a small microcontroller board
that sits between a PC running DNC and a Fanuc 0-M controller.  The
controller is failing and no longer retains macros so the tool changer
stopped working, my circuit swallows the T command and does the tool
change but otherwise passes the commands onto the Fanuc.  I'd like to
understand whats going on with DNC.


-- 
Ormund


------------------------------------------------------------------------------
Find and fix application performance issues faster with Applications Manager
Applications Manager provides deep performance insights into multiple tiers of
your business applications. It resolves application problems quickly and
reduces your MTTR. Get your free trial!
https://ad.doubleclick.net/ddm/clk/302982198;130105516;z
_______________________________________________
Emc-users mailing list
Emc-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/emc-users

Reply via email to