Hi Dave
I'd say from bottom to top but just my 2c

I'd suggest you look into heat exchangers

they are passive and do not let outside air in
nor inside air out

both airs hit a heat sink barrier on the cabinet wall

inside air temp is affected by the heatsinks temp
but no air passes from inside to outside

i use them on the edm's as the outside air is oily sticky carbon filled
plus whatever other cruft is in the shop air

keeps insides dead clean and cool enough for electrics ( not cold, just 
nice )

again my 2c

tjtr33 tomp

On 07/15/16 01:06, dave wrote:
> I'm trying to bring my Mazak V5 back online.
> Is usual practice to blow the cooling air up thru the unit or suck it
> down and out?
> Both ends have gravel strainers (:-)) on them so that is no help.
> TIA
>
> Dave
>


------------------------------------------------------------------------------