On Sat, 9 Mar 2019 at 16:31, John Dammeyer <jo...@autoartisans.com> wrote:

> How does a simple test like:
>
> if (COOLANT_SWITCH == 1) PUMP1 = 1; else PUMP1 = 0;
>
> become abstracted through the HAL into the actual low level?

Skipping all the other stuff that I can't answer....

In HAL that is "net some_signal an_input => an_output"

Where the => is optional.

A concrete example:

net coolant_on iocontrol,0.coolant-flood => hm2_5i35.0.7i76.0.1.gpi0-00-out


--
atp
"A motorcycle is a bicycle with a pandemonium attachment and is
designed for the especial use of mechanical geniuses, daredevils and
lunatics."
— George Fitch, Atlanta Constitution Newspaper, 1916