But this motor comes from Japan and, not knowing anything else, might
very well be designed for the European market.
Peter
Am 20.01.2020 um 19:31 schrieb Dr. Andreas O. Lindner:
Hello, green-yellow is protected ground only in central Europe. In US it is a
bare wire !
Just my 2 cents,
Andreas
Am 20.01.2020 um 18:48 schrieb Peter Blodow <p.blo...@dreki.de>:
Isn't there something written on the green-yellow wire? In any case: don't
connect any power to this wire, its PROTECTIVE GROUND!
Peter
Am 20.01.2020 um 18:21 schrieb grumpy--- via Emc-users:
thanks men
got it
neutral to black and blue
one side of capacitor to red
other side of capacitor to yellow
connect line to red or yellow
_______________________________________________
Emc-users mailing list
Emc-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/emc-users