On Thursday 17 September 2020 08:28:00 andy pugh wrote: > On Thu, 17 Sep 2020 at 10:34, Gene Heskett <ghesk...@shentel.net> wrote: > > halui.joint.0.unhome > > Consider using VOLATILE_HOME > > http://linuxcnc.org/docs/2.8/html/config/ini-config.html#_joint__lt_nu >m_gt_section
Thanks Andy. But then I'll need to "net" into this somehow, in order to stop the whole maryann, which is also all machine power, vfd included: net user-enable <= iocontrol.0.user-request-enable => estop-latch.0.reset net enable-latch <= estop-latch.0.ok-out => iocontrol.0.emc-enable-in If I'm reading the halmeter menu right, thats halui.estop.activate But thats yet another or2 to combine them since it won't let me hit it twice, once for each error. I think thats done, I'll test after breakfast. Thanks Andy Cheers, Gene Heskett -- "There are four boxes to be used in defense of liberty: soap, ballot, jury, and ammo. Please use in that order." -Ed Howdershelt (Author) If we desire respect for the law, we must first make the law respectable. - Louis D. Brandeis Genes Web page <http://geneslinuxbox.net:6309/gene> _______________________________________________ Emc-users mailing list Emc-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/emc-users