On Thursday 17 September 2020 08:28:00 andy pugh wrote:

> On Thu, 17 Sep 2020 at 10:34, Gene Heskett <ghesk...@shentel.net> 
wrote:
> > halui.joint.0.unhome
>
> Consider using VOLATILE_HOME
>
> http://linuxcnc.org/docs/2.8/html/config/ini-config.html#_joint__lt_nu
>m_gt_section

Thanks Andy.

But then I'll need to "net" into this somehow, in order to stop the whole 
maryann, which is also all machine power, vfd included:

net user-enable <= iocontrol.0.user-request-enable => estop-latch.0.reset
net enable-latch <= estop-latch.0.ok-out => iocontrol.0.emc-enable-in 

If I'm reading the halmeter menu right, thats halui.estop.activate
But thats yet another or2 to combine them since it won't let me hit it 
twice, once for each error. I think thats done, I'll test after 
breakfast.

Thanks Andy

Cheers, Gene Heskett
-- 
"There are four boxes to be used in defense of liberty:
 soap, ballot, jury, and ammo. Please use in that order."
-Ed Howdershelt (Author)
If we desire respect for the law, we must first make the law respectable.
 - Louis D. Brandeis
Genes Web page <http://geneslinuxbox.net:6309/gene>


_______________________________________________
Emc-users mailing list
Emc-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/emc-users

Reply via email to