On Friday 03 September 2021 11:29:55 andy pugh wrote:

> I have just advised someone on the forum that he needs a 1ppr index to
> rigid tap, as his encoder is mounted to the motor, not to the spindle.
>
> But then I started wondering if this is technically correct. I have a
> feeling that single=pass rigid tapping will be fine, but mutli-pass
> won't work?
>
> Has anyone tried this?

I am doing it on the G0704, encoder is on the spindle motor but I do use 
multipass for threading on 1/4" and bigger taps, so my index IS from the 
spindle. This does result in some huge scale settings, wnich I switch with a 
gear shift tally switches but that doesn't seem to bother LinuxCNC.

Cheers, Gene Heskett
-- 
"There are four boxes to be used in defense of liberty:
 soap, ballot, jury, and ammo. Please use in that order."
-Ed Howdershelt (Author)
If we desire respect for the law, we must first make the law respectable.
 - Louis D. Brandeis
Genes Web page <http://geneslinuxbox.net:6309/gene>