Hello!

I thought that I can remap M6 for rack tool change with subroutines,
but it turned out somewhat harder than I expected and now I have no
idea what is wrong.

In INI file I have:

[RS274NGC]
PARAMETER_FILE    = sim.var
SUBROUTINE_PATH   =
../../nc_files/subroutines:../../nc_files/ngcgui_lib/utilitysubs
# SUBROUTINE_PATH   = /home/cnc/linuxcnc/nc_files
# SUBROUTINE_PATH   = /home/cnc/linuxcnc/configs/Biesse/ncam/lib
USER_M_PATH       = ../../nc_files/ngcgui_lib/mfiles

REMAP=M6 modalgroup=6 ngc=tool_change

Tool_change.ngc file is placed in ../nc_files/subroutines
And the contents of the tool_change.gc file are here:
https://pastebin.com/St834Wkj

What I am getting now on startup is this error:
Near line 0 of /usr/share/axis/images/axis.ngc:
Zero timeout with wait type != immediate return

And the preview is empty. If I try to open any other file. I get the
same complaint.
Everything is fine, if I comment out the REMAP line in INI file -
LinuxCNC starts up correctly.

Am I missing something in the REMAP line in INI file? Some additional
arguments? Is the subroutine not correct? I have checked every example
I could find on the web and in forums and I do not understand what is
wrong. I would appreciate any hints, where to look next.

Viesturs


_______________________________________________
Emc-users mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/emc-users

Reply via email to