Hello! I thought that I can remap M6 for rack tool change with subroutines, but it turned out somewhat harder than I expected and now I have no idea what is wrong.
In INI file I have: [RS274NGC] PARAMETER_FILE = sim.var SUBROUTINE_PATH = ../../nc_files/subroutines:../../nc_files/ngcgui_lib/utilitysubs # SUBROUTINE_PATH = /home/cnc/linuxcnc/nc_files # SUBROUTINE_PATH = /home/cnc/linuxcnc/configs/Biesse/ncam/lib USER_M_PATH = ../../nc_files/ngcgui_lib/mfiles REMAP=M6 modalgroup=6 ngc=tool_change Tool_change.ngc file is placed in ../nc_files/subroutines And the contents of the tool_change.gc file are here: https://pastebin.com/St834Wkj What I am getting now on startup is this error: Near line 0 of /usr/share/axis/images/axis.ngc: Zero timeout with wait type != immediate return And the preview is empty. If I try to open any other file. I get the same complaint. Everything is fine, if I comment out the REMAP line in INI file - LinuxCNC starts up correctly. Am I missing something in the REMAP line in INI file? Some additional arguments? Is the subroutine not correct? I have checked every example I could find on the web and in forums and I do not understand what is wrong. I would appreciate any hints, where to look next. Viesturs _______________________________________________ Emc-users mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/emc-users