Hey Luca I'll make one for you.

Do you want a full on complicated program or something shorter

On Mon, 12 Oct 2026, 12:40 pm Luca Toniolo, <[email protected]> wrote:

> Hey Andrew,
>
> Do you have a sample program to test the lookahead?
>
>
> Luca
>
> On 9/30/2026 4:29 PM, andrew beck wrote:
> > Hey Luca
> >
> > I have a 4 axis vmc.  Currently biggest issues is the look ahead when
> > moving 4th axis with other axis as lookahead reverts to just a few
> blocks.
> > I'm not using your new scurce code on this.   I use g94 for 4axis I
> think.
> > But we tried g93 also.
> > Definitely makes a bit difference
> > But this would be different again I guess
> >
> > I think I would want to be able to set the dia from gcode then I would
> link
> > it in with the post processor and make it automatically set from stock
> dia
> > as you say.  Might be a bit of a pain to edit ini file every time.
> >
> > On Wed, 30 Sept 2026, 9:22 pm Luca Toniolo, <[email protected]> wrote:
> >
> >> I'm deciding whether to work on a LinuxCNC feature and would like to
> >> know first whether anyone would actually use it.
> >>
> >> Today, when a rotary axis moves together with X, Y or Z, F applies to
> >> the linear axes only, and a rotary move on its own runs at F in degrees
> >> per minute. On a 4th-axis wrap, where the surface of a cylinder is cut
> >> with X and A, the surface speed therefore doesn't match F. The usual
> >> workaround is inverse time (G93) from the CAM.
> >>
> >> The idea is a reference radius for each rotary axis, set in the INI. For
> >> example, `[AXIS_A] FEED_RADIUS = 25` puts A in the feed calculation as
> >> if it were a length at 25 mm from its centre. A move of A alone at F100
> >> would then run at 100 mm/min on the surface at that radius, and X with A
> >> would run at F along the combined path. Siemens (FGREF) and Fanuc (a
> >> parameter) do the same.
> >>
> >> Questions:
> >> 1. Would you use this, or does G93 from your CAM already cover it for
> you?
> >> 2. What machine: 4th-axis wrap, rotary table, something else?
> >> 3. The useful radius is usually the stock radius, which changes per job.
> >> Is a fixed INI value good enough, or would you need to set it from
> G-code?
> >>
> >> A short "yes, I'd use it", "no" or "G93 is fine" helps. If nobody needs
> >> it, I'll leave it.
> >>
> >> Luca
> >>
> >>
> >> _______________________________________________
> >> Emc-users mailing list
> >> [email protected]
> >> https://lists.sourceforge.net/lists/listinfo/emc-users
> >>
> > _______________________________________________
> > Emc-users mailing list
> > [email protected]
> > https://lists.sourceforge.net/lists/listinfo/emc-users
>
>
> _______________________________________________
> Emc-users mailing list
> [email protected]
> https://lists.sourceforge.net/lists/listinfo/emc-users
>

_______________________________________________
Emc-users mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/emc-users