Hello Javed ! Save the config, Shut down the chassis and remove the working module. Then connect via serial cable and terminal software to the 7G module and switch power on. In the terminal session you can see what`s going on during boot.
Volker Volker Kull BELL Computer-Netzwerke GmbH Ohmstr. 6 - 76229 Karlsruhe Tel: 0721/6624993-0 Fax: 0721/6624993-30 Email: [EMAIL PROTECTED] ----- Originalnachricht ----- Von: Javed Khan <[EMAIL PROTECTED]> An: Enterasys Customer Mailing List <[email protected]> Gesendet: Wed Nov 12 16:33:41 2008 Betreff: [enterasys] 7G4270-12 module shows RED CPU LED Dear All, N7 chassis is populated with one 7G4270-12 MTRG fiber module & one 7H4382-48 module. Now the 7G4270-12 MTRG fiber module is showing RED CPU LED. Pls let know the possible causes for the same & how to troubleshoot. Regards, Javed Khan 91-9920111017 --- To unsubscribe from enterasys, send email to [EMAIL PROTECTED] with the body: unsubscribe enterasys [EMAIL PROTECTED] --- To unsubscribe from enterasys, send email to [EMAIL PROTECTED] with the body: unsubscribe enterasys [EMAIL PROTECTED]