Nick, More information is available on our knowledgebase in the following articles:
https://knowledgebase-enterasys.talismaonline.com/article.aspx?article=11501&p=1 "SecureStack PoE Port 1 Not Operating After f/w x.02.03.0010 Upgrade" https://knowledgebase-enterasys.talismaonline.com/article.aspx?article=11507&p=1 "Special Conditions for SecureStack f/w x.02.03.0010 Availability" Regards, Mike Michael Lytle Senior Manager, Global Support Engineering Enterasys Secure Networks Phone: +1 978 684 1456 Mobile: +1 603 973 1407 From: Lytle, Mike Sent: Tuesday, January 13, 2009 7:59 AM To: Enterasys Customer Mailing List Subject: RE: Latest C2 fw 5.02.03.0010 release Nick, Version 5.02.03.0010 is available to customers, we are asking customers / partners to contact GTAC for this image, so we can ensure they understand the following warnings. Initially the first warning was not documented in the published release notes, but we will be posting an updated version this morning. We do expect to release another image soon that will not have this particular limitation. GTAC will provide this firmware release to customers directly until we have posted a newer version that does not have the first limitation below. Warning: If you are upgrading a stack or standalone switch that is PoE capable, there is a risk that "ge.1.1" will not be available after upgrading to 5.02.03. Make sure that you are not managing the stack / switch through "ge.1.1" since you may lose contact with the switch remotely. To resolve the problem you must reboot the switch or stack a second time after the upgrade. Note: Firmware 5.02.03 and above includes a new PoE driver which will require additional bootup time as the driver is being updated on PoE units within the stack. Once the initial boot of the code has completed and the PoE driver is updated, the delay should not be seen again. Michael Lytle Senior Manager, Global Support Engineering Enterasys Secure Networks Phone: +1 978 684 1456 Mobile: +1 603 973 1407 From: Nick Allen [mailto:[email protected]] Sent: Tuesday, January 13, 2009 5:43 AM To: Enterasys Customer Mailing List Subject: [enterasys] Latest C2 fw 5.02.03.0010 release Anyone know why this has been pulled from the support site? I've got it installed on a few switches / stacks and we were about to install it on a C2 with routing license installed for OSPF. (Like the new "show port cablestatus" feature by the way) Nick. * --To unsubscribe from enterasys, send email to [email protected]<mailto:[email protected]> with the body: unsubscribe enterasys [email protected] -- If emails save time, not printing them saves trees. Please don't print this email if you don't really need to. TBWA\LONDON www.tbwa-london.com _______________________________________________________________________ This e-mail is intended only for the named person or entity to which it is addressed and contains valuable business information that is proprietary, privileged, confidential and/or otherwise protected from disclosure. If you received this e-mail in error, any review, use, dissemination, distribution or copying of this e-mail is strictly prohibited. Please notify us immediately of the error via e-mail to [email protected] and please delete the e-mail from your system, retaining no copies in any media. We appreciate your cooperation. Reg. Office: TBWA UK GROUP Ltd, 76-80 Whitfield Street, London, W1T 4EZ Company Reg. #: 4332188 (UK) Company VAT #: GB 656 8994 61 --- To unsubscribe from enterasys, send email to [email protected] with the body: unsubscribe enterasys [email protected]