Good Morning Javed, This means either one of the fans, or a fan speed sensor is failing. In either case the fan tray needs to be replaced.
Regards, Larry Baker Tier 3 Routing Support Enterasys Networks From: Javed Khan [mailto:[email protected]] Sent: Wednesday, August 19, 2009 5:17 AM To: Enterasys Customer Mailing List Subject: [enterasys] SSR 8600 switch Dear Team, This is regarding the Enterasys XP-8600 SSR switch. The following error coming continuously. ''%SYS-I-FANSOKAY, system fans are operational 2009-08-13 10:54:23 %SYS-W-FANSFAILED, system fan(s) have failed or fan tray is not installed '' Please revert. Regards, Javed Khan 91-9920111017 * --To unsubscribe from enterasys, send email to [email protected]<mailto:[email protected]> with the body: unsubscribe enterasys [email protected] --- To unsubscribe from enterasys, send email to [email protected] with the body: unsubscribe enterasys [email protected]