Hi, We already encountered a similar behaviour on a C2G124-48. After an upgrade only the first 24 front-panel ports was working. This was a hardware issue "In hpcBroadInit:990, could not find the board". Is your unit was rebooted in a recent past before the upgrade ? I'm thinking that you should encountered this behaviour without the upgrade ...
It is the POST log of the unit discuss : Version 01.00.47 12-11-2008 Computing MD5 Checksum of operational code... Select an option. If no selection in 2 seconds then operational code will start. 1 - Start operational code. 2 - Start Boot Menu. Select (1, 2): Operational Code Date: Wed Apr 8 20:33:00 2009 Uncompressing..... 50% 100% |||||||||||||||||||||||||||||||||||||||||||||||||| Attaching interface lo0...done Adding 62651 symbols for standalone. SOC unit 0 attached to PCI device BCM5695_B0 SOC unit 1 attached to PCI device BCM5695_B0 SOC unit 2 attached to PCI device BCM5670_A1 In hpcBroadInit:990, could not find the board Adding BCM transport pointers Configuring CPUTRANS TX Configuring CPUTRANS RX Bye, ----------------------------------------------------- Sylvain CONTI - Rétis Communication T : +33.1.64.53.14.12 - F: +33.1.69.32.14.02 Parc Gutenberg - 11 voie la Cardon 91120 Palaiseau http://www.retis.fr / mailto:sco...@retis.fr -----Message d'origine----- De : Connie Mkhize [mailto:connie.mkh...@bytes.co.za] Envoyé : jeudi 14 janvier 2010 10:58 À : Enterasys Customer Mailing List Objet : RE: [enterasys] C2G123-48P Thanks a million for your response Andre. Yes that is exactly how I upgraded the firmware otherwise the switch would have gone on a continuous rebooting loop/cycle. Have restored to factory default. No luck :-( -----Original Message----- From: Keller, Andre ( OTLG ) [mailto:andre.kel...@volkswagen-otlg.de] Sent: Thursday, January 14, 2010 11:52 AM To: Enterasys Customer Mailing List Subject: AW: [enterasys] C2G123-48P Hi Connie, did you update the firmware in several steps? I think you´ll have to update from 3.x -> 4.x -> 5.0.x and finally 5.2.x if i remember correctly. There was a POE Module Update in there somewhere which might be the reason for your port loss. Try restoring the switch to factory defaults might be useful as well. Hope that helps, good luck! Mit freundlichen Grüßen i.A. André Keller Informationssysteme Lokaler Betrieb und Support Volkswagen Original Teile Logistik GmbH und Co. KG Vertriebszentrum Nord Am Stammgleis 6 22844 Norderstedt Tel.: +49 (40) 52200-3211 Fax: +49 40 52200-3209 <http://www.volkswagen-otlg.de> > -----Ursprüngliche Nachricht----- > Von: Connie Mkhize [mailto:connie.mkh...@bytes.co.za] > Gesendet: Donnerstag, 14. Januar 2010 10:44 > An: Enterasys Customer Mailing List > Betreff: [enterasys] C2G123-48P > > Hi guys > > Has anyone encountered the following problem - it has me baffled. > > I have a C2G123-48P switch and I recently upgraded the code > from 03.33.xx.xx to c2-series_05.02.07.0006 (specified as 48p). > After the upgrade (which was done in the recommended steps) > the last 24 ports stopped working. > > I assumed I had made a mistake by loading > c2-series_05.02.07.0006 (specified as 24p) so I reloaded the > correct image but ports 25-48 still don't work. > Tried enabling and disabling the ports as well as reloading > the switch, to no avail. > > Each set of 16 ports is on the same card and I assume that if > 8 ports are blown on one card then the other 8 will most > probably blow as well (that's just my assumption). > > Should the ports be faulty - amazing how all 25-48 would be faulty. > Please assist. > > Thanks > > Kindest Regards > Connie > > The information contained in this message and or attachments > is intended > only for the person or entity to which it is addressed and may contain > confidential and/or privileged material. Any review, retransmission, > dissemination or other use of, or taking of any action in > reliance upon, > this information by persons or entities other than the > intended recipient > is prohibited. If you received this in error, please contact > the sender and > delete the material from any system and destroy any copies. > > --- > To unsubscribe from enterasys, send email to lists...@unc.edu > with the body: unsubscribe enterasys andre.kel...@volkswagen-otlg.de > --- To unsubscribe from enterasys, send email to lists...@unc.edu with the body: unsubscribe enterasys connie.mkh...@bytes.co.za The information contained in this message and or attachments is intended only for the person or entity to which it is addressed and may contain confidential and/or privileged material. Any review, retransmission, dissemination or other use of, or taking of any action in reliance upon, this information by persons or entities other than the intended recipient is prohibited. If you received this in error, please contact the sender and delete the material from any system and destroy any copies. --- To unsubscribe from enterasys, send email to lists...@unc.edu with the body: unsubscribe enterasys sco...@retis.fr --- To unsubscribe from enterasys, send email to lists...@unc.edu with the body: unsubscribe enterasys arch...@mail-archive.com