Stefan,

I am just doing a follow up on the issue you did report and was wondering
if you happen to open a ticket on this issue?

I am very interested in your issue and would like to assist you.

Please open a ticket and have someone contact me
Jason Parker
Tier 3

On Thu, Jul 5, 2012 at 8:05 AM, Parker, Jason <[email protected]> wrote:

> Stefan,
>
> Could you please open a case and let them know that I would like to assist
> in finding the root cause and what we could do to assist you. Please
> include a trace of this event witjh the SNMP traffic so we can review it.
> Did you happen to clear SNMPv1 from the switch?
> Thank You
> Jason Parker
>
> On Thu, Jul 5, 2012 at 5:15 AM, Stefan Hofem <[email protected]
> > wrote:
>
>> Hi Joyon,
>>
>> yep, our switches are running SNMP - SNMPv3. The "normal" SNMP-Traffic
>> from NetSight, our SNMP-Monitoring-Tool and Cacti-Poller doesn't bother the
>> switches. Only the new, huge amount of SNMPv1 traffic between PCs and
>> printers make the switch-CPU's glow red-hot in the dark... ;)
>>
>> Regards
>> Stefan
>>
>> ---
>> To unsubscribe from enterasys, send email to [email protected] with the
>> body: unsubscribe enterasys [email protected]
>>
>
>
>
> --
>
> *Jason Parker*
>
> Enterasys Networks |
>
> Email: [email protected]
>
>
>    - --To unsubscribe from enterasys, send email to [email protected] with
>    the body: unsubscribe enterasys [email protected]
>
>


-- 

*Jason Parker*

Enterasys Networks |

Office: 978-684-1468

Email: [email protected]

---
To unsubscribe from enterasys, send email to [email protected] with the body: 
unsubscribe enterasys [email protected]

Reply via email to