Hi Enterasys Community,

Please advise on how to enable ICMP reply from Enterasys B5G124-24 after 
applying an extended access -list as it does not support command ip access-list 
extended 'established' command.
Our challenge is it not allowing us to receive ICMP reply after setting the 
access list. I checked on different chassis the Enterasys S4 and on this it 
works as the command ip access-list extended with established is supported 
however not on the B5G124-24 please advise on a work around.

With best regards,
Pheko Mamabolo

Siemens (Proprietary) Limited
Global Service Information Technology
IT Infrastructure Service Delivery
Regions Asia, Pacific, Middle East and Africa
Operational Service Back End Essential
GS IT IN SD R AAE OPS BEE
Tel.: +27 11 652-2938
Fax: +27 86 506-6018
Mobil: +27 82 487-9822
mailto:[email protected]

From: Mamabolo, Pheko (GS IT IN SD AAE OPS COL) 
[mailto:[email protected]]
Sent: 13 January 2016 02:51 PM
To: Enterasys Customer Mailing List
Cc: Caeiro, Jorge; Guemadi, Mohamed-Lamine (GS IT R AAE BN BAN)
Subject: RE:[Enterasys] Access - List Query I do not receive ICMP reply after 
applying my access list

Dears,

Please assist I am not able to receive ICMP echo reply after applying ACL that 
specifically permits certain networks to do this.
An example of my access list

access-list 111 permit ICMP 172.16.49.0 0.0.0.3 67.67.67.67
interface vlan 431
ip access-group 111 in sequence 1
ip address 67.67.67.67

I have also applied ip ICMP redirect enable globally and also on the interface.

Is there some type established command missing and what is the syntax as the B5 
Layer 3 switch I am working on is not supporting such a command.

"permit tcp 172.16.49.0 0.0.0.3 established 67.67.67.67 0.0.0.31" this is not 
available on the B5G124-24 switch?

Please advise!!

With best regards,
Pheko Mamabolo

Siemens (Proprietary) Limited
Global Service Information Technology
IT Infrastructure Service Delivery
Regions Asia, Pacific, Middle East and Africa
Operational Service Back End Essential
GS IT IN SD R AAE OPS BEE
Tel.: +27 11 652-2938
Fax: +27 86 506-6018
Mobil: +27 82 487-9822
mailto:[email protected]



------------------------------------
Disclaimer and Confidentiality Note
This e-mail communication, its attachments, if any, and any rights attaching to 
it are, unless the context clearly indicates otherwise, the property of Siemens 
(Pty) Ltd. It is confidential, private and intended for the addressee only. If 
you are not the intended recipient and receive this communication in error, you 
are hereby notified that any review, copying, use, discloser or distribution in 
any manner whatsoever is strictly prohibited. Please notify the sender 
immediately that you have received this e-mail in error and delete the e-mail 
and any copies of it. Views and opinions expressed in this e-mail are those of 
the sender unless clearly stated as those of Siemens (Pty) Ltd. Siemens (Pty) 
Ltd accepts no liability for any loss or damage whatsoever, and howsoever 
incurred or suffered resulting or arising from the use of this e-mail 
communication and/or its attachments. Siemens (Pty) Ltd does not warrant the 
integrity of this e-mail communication nor that it is free of errors, viruses, 
interception or interference. Siemens (Pty) Ltd, its divisions and subsidiary 
companies ("Siemens") expressly excludes sections 11, 12, and 13 of the 
Electronic Communications and Transactions Act, 25 of 2002 ("the ECT") in 
respect of e-contracting. No data message or electronic communication will be 
recognised as having a legal contractual status under the ECT Act. All 
agreements concluded by Siemens will only be legally binding when reduced to 
physical writing and physically signed by a duly authorised representative of 
Siemens. For more information about Siemens (Pty) Ltd, visit our website at 
www.siemens.com<http://www.siemens.com>

Siemens (Proprietary) Limited (Incorporated in South Africa)
South African Company Registration Number: 1923/007514/07
Registered Address: 300 Janadel Avenue, Halfway House 1685
VAT Registration Number: 4790104428
Chairman: KJ Helmrich*
Chief Executive Officer: SU Dall'Omo*
Chief Financial Officer: SJ Mueller*
Executive Director: R Nkuhlu, C Klaas
Non-Executive Directors: TK Rathmann*; Dr MI Survé
Alternate Directors: I Amod; MK Becker*
* German

------------------------------------

  *   --To unsubscribe from Enterasys, send email to 
[email protected]<mailto:[email protected]> with the body: unsubscribe Enterasys 
[email protected]<mailto:[email protected]>

------------------------------------
Disclaimer and Confidentiality Note
This e-mail communication, its attachments, if any, and any rights attaching to 
it are, unless the context clearly indicates otherwise, the property of Siemens 
(Pty) Ltd. It is confidential, private and intended for the addressee only. If 
you are not the intended recipient and receive this communication in error, you 
are hereby notified that any review, copying, use, discloser or distribution in 
any manner whatsoever is strictly prohibited. Please notify the sender 
immediately that you have received this e-mail in error and delete the e-mail 
and any copies of it. Views and opinions expressed in this e-mail are those of 
the sender unless clearly stated as those of Siemens (Pty) Ltd. Siemens (Pty) 
Ltd accepts no liability for any loss or damage whatsoever, and howsoever 
incurred or suffered resulting or arising from the use of this e-mail 
communication and/or its attachments. Siemens (Pty) Ltd does not warrant the 
integrity of this e-mail communication nor that it is free of errors, viruses, 
interception or interference. Siemens (Pty) Ltd, its divisions and subsidiary 
companies ("Siemens") expressly excludes sections 11, 12, and 13 of the 
Electronic Communications and Transactions Act, 25 of 2002 ("the ECT") in 
respect of e-contracting. No data message or electronic communication will be 
recognised as having a legal contractual status under the ECT Act. All 
agreements concluded by Siemens will only be legally binding when reduced to 
physical writing and physically signed by a duly authorised representative of 
Siemens. For more information about Siemens (Pty) Ltd, visit our website at 
www.siemens.com

Siemens Proprietary Limited (Incorporated in South Africa)
Company Registration Number: 1923/007514/07
Registered Address: 300 Janadel Avenue, Halfway House 1685
VAT Registration Number: 4790104428
Chairman: KJ Helmrich*
Chief Executive Officer: SU Dall'Omo*
Chief Financial Officer: SJ Mueller*
Executive Director: R Nkuhlu, C Klaas
Non-Executive Directors: TK Rathmann*; Dr MI Survé
Alternate Directors: I Amod; MK Becker*
Company Secretary: U Akwiwu
* German

------------------------------------

---
To unsubscribe from enterasys, send email to [email protected] with the body: 
unsubscribe enterasys [email protected]

Reply via email to