If everything works until you put it into the plane, then start tracing
wires. It's obviously wired wrong.
Start at your voltage regulator- there are 3 terminals B, G, F
terminal B goes to your bus bar, via the ammeter and then through the
master switch and then ends up at the battery
B---------------ammeter-------------------busbar--------------master
switch-----------battery
terminal G goes to the armature output stud on the generator (in the
generator, you should see this stud connected to 1 of the brushes)
G------------------------------------------------------------------------
---------------generator stud
terminal F goes through your generator switch (you only need 1 generator
switch- use the one on your panel) to the only other generator stud
the field stud
F----------------------------------------------------generator
switch--------------------generator stud
this is how it's supposed to be.
jan z
==========================================================================
====
To leave this forum go to: http://ercoupers.com/lists.htm
Search the archives on http://escribe.com/aviation/coupers-tech/