----[Please read http://ercoupers.com/disclaimer.htm before following any advice in this forum.]----
I don't recall this being discussed before or my memory has slipped. Type certificate data sheet No. E-233 covers basically all of the C-75 and C-85 engines. Note 3 of the TCDS lists Four generators as being eligible for use on these engines. We usually talk about the Delco-Remy generator no. 1101876 as being a 12V, 13amp generator and in AC 43.13-1B par.11-33 we limit the output of the generator to 80% of it's rated capacity. The TCDS lists the 1101876 generator as being a 15A unit, not 13amps and the 80% limit would therefore be 12 amps. I had been a bit confused and figured that the 80% would be taken from the 13amp figure instead of 15amps. The other generators and amperage listed are: NO. 1101890, 20amps; 1101879, 25amps; and the 1101898, 35amps. Another interesting fact is the weight of each generator. The 1101876 and the 1101890 both weigh in at 10 lb. with the 1101879 at 14 lb. and the 1101898 at 16 lb..
Rich Blair N99997 & N23287 Kingsland, Ga ============================================================================== To leave this forum go to: http://ercoupers.com/lists.htm