>Scott -

>When I try to use the map-to-map reprojection, I get am error: "There
>currently is no mapping between the input coordinate system and the output
>coordinate system.  Please try selecting another output datum and/or
>projection.

There is no projection defined for Missouri Central NAD83 meters, only
one for feet.  To add this to ER Mapper's projection database:

1) Close ER Mapper.
2) Add this line to the tranmerc.dat file in ER Mapper's
   GDT_DATA directory:

TMMISOCM83,0,500000,0.999933333,-1.614429558,0.625409648,20925391.87,0.081819191,298.2572221,1,

3) Add this line to project.dat (also in GDT_DATA):

TMMISOCM83,tranmerc,1.0 ,20925391.87 ,0.0818191910429546,298.2572221 ,1

4) Restart ER Mapper, assign that new projection to your
    dataset (using the Dataset Header Editor), then run
    the reprojection to UTM15.

Regards,



Eric Augenstein
---------------------------------------------------------------
Earthstar Geographics
5330 Carroll Canyon Road
Suite 200
San Diego, CA 92121-3758 USA
32:53:35N  117:11:38W

E-mail: [EMAIL PROTECTED]
Internet: www.es-geo.com
ER Mapper Wizards: www.es-geo.com/wizard.html
Tel: +1 858-455-9970
Fax: +1 858-455-9971
---------------------------------------------------------------

-----------------------------------------------------------