Hi List!

A minor problem I have noticed:

Displaying a trace I have made, with some DCE-RPC packets, but displayed as diameter 
packets.

Some messages on the console:

Diameter: Unable to find name for command code 0x00000000, Vendor "1207959552"!
Diameter: Bad packet: Bad Flags(0x10) or Version(5)
Diameter: Unable to find name for command code 0x00000000, Vendor "1207959552"!
Diameter: Bad packet: Bad Flags(0x10) or Version(5)
Diameter: Unable to find name for command code 0x00000000, Vendor "671088640"!
Diameter: Bad packet: Bad Flags(0x10) or Version(5)
Diameter: Unable to find name for command code 0x00000000, Vendor "671088640"!
Diameter: Bad packet: Bad Flags(0x10) or Version(5)

-The diameter dissector should not decode the corresponding packets as diameter 
packets, as they are using the ports 1812 (diameter) and 135 (rpc), and are really 
DCE-RPC packets.
I have fixed this by setting the diameter port in the preferences to a different value 
(I'm not using diameter).

-In the console comes a lot of messages like the ones above, which shouldn't be there 
I think.