Florian Pose schrieb:
Hello,

On Mon, May 04, 2009 at 02:22:47PM +0200, Andy Rohr wrote:
I'm using dlsd to log measurements. This works fine with a small amount of channels. But I want to record 180 channels of data. As soon as I configure configure this many channels, I get into trouble with the dlsd_logger:

May 4 14:03:02 mindclue-andy-linux dlsd_logger[9475]: ERROR: Processing data: Logger: GenSaver: Could not write to global index file "/media/sda8/data/dls_data/job107/channel111/chunk1241438543765428/level1/data_mean.idx": Could not create file "/media/sda8/data/dls_data/job107/channel111/chunk1241438543765428/level1/data_mean.idx" for appending: Too many open files

The dlsd has a '-n' option for that. See 'dlsd -h' or the documentation.
Usually it's just adding '-n 4096' or something to the sysconfig file.


Oh, simple and nice solution for that problem!

Thanks!