Hello, Does the ethercat master stack support a bus-shift mode of Distributed Clocks? Our application is currently using a master-shift, where the master clock is adjusted to match the reference slave device. Is there sample code for the reverse, where the reference slave device clock is adjusted to match the master? Thank you, Tom
Thomas Greier | Sect. Head, Engrg. direct: +17168052606 email: [email protected]<mailto:[email protected]> Moog Industrial Group Seneca St & Jamison Rd East Aurora, NY 14052 www.moog.com/industrial<http://www.moog.com/industrial> Sign up for our Industrial Newsletter<http://www.ideasinmotioncontrol.com/> [http://www.moog.com/content/dam/logo.png] Confidentiality Notice: This electronic mail transmission is intended for the use of the individual or entity to which it is addressed and may contain confidential and/or proprietary information belonging to the sender. If you are not the intended recipient, you are hereby notified that any disclosure, use, copying, distribution, or the taking of any action in reliance on the contents of this information is strictly prohibited. If you have received this transmission in error, please notify the sender immediately by e-mail and delete the original message. Thank you for your cooperation.
_______________________________________________ etherlab-users mailing list [email protected] http://lists.etherlab.org/mailman/listinfo/etherlab-users