Hi erveryone, I want to setup TwinSafe Logic Terminals, EL6900, EL2904 and EL1904.I've created a Safety-Project with TwinCat3 and downloaded the safety-logic to the EL6900. I use the default settings from TwinCat3. Now I want to implement it to the etherlab-master. The Default PDO-Mapping of the EL6900 - Terminal:
SM0: PhysAddr 0x1000, DefaultSize 256, ControlRegister 0x26, Enable 1 SM1: PhysAddr 0x1100, DefaultSize 256, ControlRegister 0x22, Enable 1 SM2: PhysAddr 0x1200, DefaultSize 2, ControlRegister 0x24, Enable 1 RxPDO 0x1600 "FSOE RxPDO-Map 001" PDO entry 0x7000:01, 8 bit, "FSOE Command" PDO entry 0x7001:01, 8 bit, "SubIndex 001" PDO entry 0x7000:03, 16 bit, "FSOE CRC 001" PDO entry 0x7000:02, 16 bit, "FSOE ConnID" RxPDO 0x1601 "FSOE RxPDO-Map 002" PDO entry 0x7010:01, 8 bit, "FSOE Command" PDO entry 0x7011:01, 8 bit, "SubIndex 001" PDO entry 0x7010:03, 16 bit, "FSOE CRC 001" PDO entry 0x7010:02, 16 bit, "FSOE ConnID" RxPDO 0x17f0 "DEVICE RxPDO-Map Standard In Vars" PDO entry 0xf201:01, 1 bit, "SubIndex 001" PDO entry 0xf201:02, 1 bit, "SubIndex 002" PDO entry 0xf201:03, 1 bit, "SubIndex 003" PDO entry 0xf201:04, 1 bit, "SubIndex 004" PDO entry 0xf201:05, 1 bit, "SubIndex 005" PDO entry 0xf201:06, 1 bit, "SubIndex 006" PDO entry 0xf201:07, 1 bit, "SubIndex 007" PDO entry 0xf201:08, 1 bit, "SubIndex 008" RxPDO 0x17ff "DEVICE RxPDO-Map Control" PDO entry 0xf200:01, 16 bit, "Control" SM3: PhysAddr 0x1d00, DefaultSize 2, ControlRegister 0x20, Enable 1 TxPDO 0x1a00 "FSOE TxPDO-Map 001" PDO entry 0x6000:01, 8 bit, "FSOE Command" PDO entry 0x6001:01, 8 bit, "SubIndex 001" PDO entry 0x6000:03, 16 bit, "FSOE CRC 001" PDO entry 0x6000:02, 16 bit, "FSOE ConnID" TxPDO 0x1a01 "FSOE TxPDO-Map 002" PDO entry 0x6010:01, 8 bit, "FSOE Command" PDO entry 0x6011:01, 8 bit, "SubIndex 001" PDO entry 0x6010:03, 16 bit, "FSOE CRC 001" PDO entry 0x6010:02, 16 bit, "FSOE ConnID" TxPDO 0x1bff "DEVICE TxPDO-Map Status" PDO entry 0xf100:01, 3 bit, "Safety Project State" PDO entry 0x0000:00, 4 bit, "Gap" PDO entry 0xf100:08, 1 bit, "Login Active" PDO entry 0xf100:09, 1 bit, "Input Size Mismatch" PDO entry 0xf100:0a, 1 bit, "Output Size Mismatch" PDO entry 0x0000:00, 4 bit, "Gap" PDO entry 0xf100:0f, 1 bit, "TxPDO State" PDO entry 0xf100:10, 1 bit, "TxPDO Toggle" When I want to add PDOs, I get following warnings: EtherCAT WARNING 0-1: Currently mapped PDO entries: 0x7000:01/8 0x7001:01/8 0x7000:03/16 0x7000:02/16. Entries to map: 0x7000:01/8 0x7001:01/8 0x7000:03/16 0x7000:02/16 0x6000:01/48 0x6000:02/48 EtherCAT WARNING 0-1: Slave does not support changing the PDO mapping! Slave Info EL6900: === Master 0, Slave 1 === Alias: 100 Device: Main State: OP Flag: + Identity: Vendor Id: 0x00000002 Product code: 0x1af43052 Revision number: 0x00130000 Serial number: 0x00000000 DL information: FMMU bit operation: no Distributed clocks: yes, delay measurement only DC system time transmission delay: 145 ns Port Type Link Loop Signal NextSlave RxTime [ns] Diff [ns] NextDc [ns] 0 EBUS up open yes 0 2874259272 0 145 1 EBUS up open yes 2 2874260152 880 145 2 N/A down closed no - - - - 3 N/A down closed no - - - - Mailboxes: Bootstrap RX: 0x1000/244, TX: 0x10f4/244 Standard RX: 0x1000/256, TX: 0x1100/256 Supported protocols: CoE, FoE General: Group: Safety Image name: EL69XX Order number: EL6900 Device name: EL6900, TwinSAFE-PLC CoE details: Enable SDO: yes Enable SDO Info: yes Enable PDO Assign: no Enable PDO Configuration: no Enable Upload at startup: no Enable SDO complete access: no Flags: Enable SafeOp: no Enable notLRW: no Current consumption: 190 mA I see, that's not possible to assign or to configure PPOs, but what is the right track to setup this system successfully? The used PDOs are not unique! Do I have to change settings in TwinCat3? I am not an Expert of this; I only want to use the Safety-Editor to create the Safety - Logic! In earlier posts here I found, that it is possible to implement Safety Terminals in the etherlab master successfully. I've already read, that the FSoE - Data (6 Bytes) between the Safety - Terminals must be managed in the cycle_task of the Application; a little bit tricky but make sense. The last point: In the Safety - Logic I used one variable to set Com/Err - Signal which is also linked to a PDO, I can't mapped! Thanks in advance for attention and help. Best regards Uwe Stegemann ____________________________________ G+D Currency Technology Uwe Stegemann Banknote-Engineering - Printing Division / Abt. CTBN 214 Giesecke+Devrient Currency Technology GmbH, Prinzregentenstraße 159, D-81677 Munich, Germany T +49 89 4119-2321 F +49 89 4119-1446 mailto:uwe.stegem...@gi-de.com http://www.gi-de.com<http://www.gi-de.com/> www.gi-de.com/currency-technology<https://www.gi-de.com/currency-technology/> [Cash Matters] <http://www.cashmatters.org/> Geschäftsführer: Dr. Wolfram Seidemann (Vorsitzender, CEO), Guido Koller (CFO), Wolfgang Kneilmann, Bernd Kümmerle Gesellschaftssitz: München, Handelsregister des AG München, HRB 148256
-- Etherlab-users mailing list Etherlab-users@etherlab.org https://lists.etherlab.org/mailman/listinfo/etherlab-users