Willie via EV wrote:
I once blew a main fuse on my conversion. Didn't find any obvious problems, replaced the fuse and never had more trouble with it.
Fuses are indeed affected by age, vibration, environment, and temperature. So it could be just that the fuse got old and tired. :-)
They "blow" when the element inside reaches its melting temperature. It blows at a lower current when it's hot. The resistance of the fuse itself generates heat, but so can a loose or corroded fuseholder.
Vibration can also cause metal fatigue. A fuse that operates near its rated current (i.e. near its melting point) for long period can gradually degrade until it fails unexpectedly at a lower current.
Water, salt spray, dirt, and other environmental hazards can also rust or corrode away part of the fuse element, making them fail.
-- Teaching children to program goes against the grain of modern education. Just imagine the chaos if they learned to think logically, plan, create, implement, test, and execute! -- Lee Hart, 814 8th Ave N, Sartell MN 56377, www.sunrise-ev.com _______________________________________________ UNSUBSCRIBE: http://www.evdl.org/help/index.html#usub http://lists.evdl.org/listinfo.cgi/ev-evdl.org Read EVAngel's EV News at http://evdl.org/evln/ Please discuss EV drag racing at NEDRA (http://groups.yahoo.com/group/NEDRA)