On Tue, 8 Oct 2019 at 15:57, EVDL Administrator via EV
<[email protected]> wrote:

> Am I missing something?  Isn't this what main contactors are for?

A short circuit of the main battery bus during an impact could weld
contactors, particularly as there may be contact bounce due to the
impact.

A fuse might not blow, because the sustained fault current isn't high enough.

A one time operable disconnect sounds like a good idea. Cutting cables
doesn't, but then that is probably just bad reporting of the actual
process.

-- 
Paul Compton
www.morini-mania.co.uk
www.paulcompton.co.uk (YouTube channel)