Perhaps configure them into the network with a full set of connectors
identical to the the existing hub, but set the cost on the new connections
to 100 (use when the other connectors are not availalbe)?

-----Original Message-----
From: Chris Jordan [mailto:[EMAIL PROTECTED]]
Sent: Thursday, 30 May 2002 11:45 PM
To: Exchange Discussions
Subject: Stand-by servers


We have a hub and spoke network of 150 Exchange 5.5 Sites. The centre Site
of the hub is just a routing Site with 2 servers (no user mailboxes). All
spoke Sites are connected to the hub Site with X.400 connectors (to one or
other of the servers).

We now need a Business Continuity / Disaster Recovery environment for the
Hub. We want to build 2 spare servers in another location, and have these
servers take over the role of the routing hub in as short a time as
possible. Our plan is to build these spare servers as copies of the live
servers (same NT name, same IP address, same Exchange configuration). They
will be kept off the network until the central hub is no more, and then the
network will be switched, and these servers will become live.

How should we build the server??
One idea is: Build a BDC in the normal domain. Then disconnect the BDC from
the network, and promote it to a PDC. Then the new (member server) Exchange
server can be built off the network and connected into the stand-alone
domain using the new PDC. The Exchange server and configuration can then be
restored, probably on a monthly basis to maintain it in (approximate) step
with the live environment.


Anyone know whether these ideas will work? Anyone got other ideas that we
should explore?
At the present time we are less worried about the spoke Sites, which is
where the users reside.


Thanks, 

Chris



_________________________________________________________________
List posting FAQ:       http://www.swinc.com/resource/exch_faq.htm
Archives:               http://www.swynk.com/sitesearch/search.asp
To unsubscribe:         mailto:[EMAIL PROTECTED]
Exchange List admin:    [EMAIL PROTECTED]

Important Message:

[This transmission or any part of it is intended solely for the named addressee.  It 
is confidential.  The copying or distribution of this transmission or any information 
it contains, by anyone other than the addressee, is prohibited.

 If you have received this transmission in error, please let us know by telephone 61 7 
3860 2111 or by reply email to the sender.  If you are not the named addressee, you 
must destroy the original transmission and its contents.

 You may not rely on electronically transmitted material unless the transmission is 
subsequently confirmed by fax or letter.  Material transmitted to you should also be 
checked by reference to a hard copy of that material printed directly from our word 
processing system.]

_________________________________________________________________
List posting FAQ:       http://www.swinc.com/resource/exch_faq.htm
Archives:               http://www.swynk.com/sitesearch/search.asp
To unsubscribe:         mailto:[EMAIL PROTECTED]
Exchange List admin:    [EMAIL PROTECTED]

Reply via email to