Hi there!

My external modem only manages to connect every second time I'm
starting pppd. 
The Chat script looks like this:

TIMEOUT 30
ABORT "NO CARRIER"
ABORT "NO DIALTONE"
ABORT ERROR
ABORT "NO ANSWER"
ABORT BUSY
ABORT "Username/Password Incorrect"
"" +++ATZ
TIMEOUT 20
OK ATD010980193434
TIMEOUT 10
CONNECT ""

Here are two sessions from /var/log/messages, the first successful,
the second not:

Oct 26 12:27:15 baer pppd[1854]: pppd 2.3.8 started by tom, uid 500
Oct 26 12:27:16 baer chat[1855]: timeout set to 20 seconds
Oct 26 12:27:16 baer chat[1855]: abort on (NO CARRIER)
Oct 26 12:27:16 baer chat[1855]: abort on (NO DIALTONE)
Oct 26 12:27:16 baer chat[1855]: abort on (ERROR)
Oct 26 12:27:16 baer chat[1855]: abort on (NO ANSWER)
Oct 26 12:27:16 baer chat[1855]: abort on (BUSY)
Oct 26 12:27:16 baer chat[1855]: abort on (Username/Password Incorrect)
Oct 26 12:27:16 baer chat[1855]: send (+++ATZ^M)
Oct 26 12:27:16 baer chat[1855]: timeout set to 10 seconds
Oct 26 12:27:16 baer chat[1855]: expect (OK)
Oct 26 12:27:17 baer chat[1855]: ATZ^M^M
Oct 26 12:27:17 baer chat[1855]: OK
Oct 26 12:27:17 baer chat[1855]:  -- got it 
Oct 26 12:27:17 baer chat[1855]: send (ATD010980193434^M)
Oct 26 12:27:17 baer chat[1855]: timeout set to 10 seconds
Oct 26 12:27:17 baer chat[1855]: expect (CONNECT)
Oct 26 12:27:17 baer chat[1855]: ^M
Oct 26 12:27:19 baer chat[1855]: ATD010980193434^M^M
Oct 26 12:27:19 baer chat[1855]: CONNECT
Oct 26 12:27:19 baer chat[1855]:  -- got it 
Oct 26 12:27:19 baer chat[1855]: send (^M)
Oct 26 12:27:19 baer pppd[1854]: Serial connection established.


Oct 26 12:27:01 baer pppd[1851]: pppd 2.3.8 started by tom, uid 500
[snip, same as above]

Oct 26 12:27:02 baer chat[1852]: ATZ^M^M
Oct 26 12:27:02 baer chat[1852]: OK^M
Oct 26 12:27:12 baer chat[1852]: alarm
Oct 26 12:27:12 baer chat[1852]: Failed
Oct 26 12:27:12 baer pppd[1851]: Connect script failed
Oct 26 12:27:13 baer pppd[1851]: Exit.

Initstring is ok (worked every time with kppp), ATD too. Already
tried different time-out settings but this doesn't seem to be the
problem: I don't understand why there's an EOL in the
second session when the modem is expected to dial. Ideas?

Regards

tom

 -- 
"This program can destroy data, and is not yet safe for general use."
(from 'freshmeat')
Thomas 'tom' Berger, [EMAIL PROTECTED]
----MandrakeUser.Org-Webservant----