On Mon, Dec 28, 2009 at 8:57 PM, Joseph Moschini <[email protected]> wrote: > Is "nano-count" suppose to return 0 value all the time ?.
No, it's supposed to return a monotonically increasing counter that increments approximately once per nanosecond. One reason it might be returning 0 is if QueryPerformanceFrequency() returns a value greater than 1,000,000,000; this results in an underflow in the calculation in the VM. Can you try running the below program and tell me what it outputs? http://factorcode.org/freqtest.exe Slava ------------------------------------------------------------------------------ This SF.Net email is sponsored by the Verizon Developer Community Take advantage of Verizon's best-in-class app development support A streamlined, 14 day to market process makes app distribution fast and easy Join now and get one step closer to millions of Verizon customers http://p.sf.net/sfu/verizon-dev2dev _______________________________________________ Factor-talk mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/factor-talk