This doesn't happen on the buildbots, is it something about my installation? Does anyone else get this? You don't have to run all tests to check, just cd <dolfin> cd test/unit/python py.test la/test_krylov_solver.py
> assert niter < 12 E assert 15 < 12 la/test_krylov_solver.py:119: AssertionError ------------------------------------------------------------------------------------------- Captured stdout call -------------------------------------------------------------------------------------------- Testing method 'petsc_amg' with 4 x 4 mesh Solving linear system of size 50 x 50 (PETSc Krylov solver). 3 iterations. Testing method 'petsc_amg' with 8 x 8 mesh Solving linear system of size 162 x 162 (PETSc Krylov solver). 4 iterations. Testing method 'petsc_amg' with 16 x 16 mesh Solving linear system of size 578 x 578 (PETSc Krylov solver). 6 iterations. Testing method 'petsc_amg' with 32 x 32 mesh Solving linear system of size 2178 x 2178 (PETSc Krylov solver). 8 iterations. Testing method 'petsc_amg' with 64 x 64 mesh Solving linear system of size 8450 x 8450 (PETSc Krylov solver). 10 iterations. Testing method 'ml_amg' with 4 x 4 mesh Solving linear system of size 50 x 50 (PETSc Krylov solver). 4 iterations. Testing method 'ml_amg' with 8 x 8 mesh Solving linear system of size 162 x 162 (PETSc Krylov solver). 6 iterations. Testing method 'ml_amg' with 16 x 16 mesh Solving linear system of size 578 x 578 (PETSc Krylov solver). 8 iterations. Testing method 'ml_amg' with 32 x 32 mesh Solving linear system of size 2178 x 2178 (PETSc Krylov solver). 11 iterations. Testing method 'ml_amg' with 64 x 64 mesh Solving linear system of size 8450 x 8450 (PETSc Krylov solver). 15 iterations.
_______________________________________________ fenics mailing list [email protected] http://fenicsproject.org/mailman/listinfo/fenics