I don't think it is a re-spacing problem - you need to UNcheck the "update automatically" in the MM rest options
On Jul 10, 2012, at 1:26 PM, Dennis Bathory-Kitsz wrote: > FinWin 2011 > > When I have a multimeasure rest at the end of a system that ends in a clef > change, I move the rest symbol back using the multimeasure rest edit context > popup. > > It works fine until I try to print it. It resets the value to zero on printing > and the mm rest overlaps the clef. This happens in the Finale file itself. > > Someone mentioned that an automatic music respacing takes place on printing, > but I've never noticed it before and it hasn't affected any other spacing in > this document. > > Anybody know what's up? > > Dennis > > > _______________________________________________ > Finale mailing list > [email protected] > http://lists.shsu.edu/mailman/listinfo/finale _______________________________________________ Finale mailing list [email protected] http://lists.shsu.edu/mailman/listinfo/finale
