On Jul 12, 2011, at 10:54 AM, Marc Saudreau wrote:
> Whatever the case, when I try to impose a fixed value, the temperature of > faces is not uniform. I guess I should have the same value on all faces I > fixed the temperature ! See the attached jpg file when temperature is fixed > on the lateral surface. The visualization is of the temperature of the cell centers and so I would expect some fluctuations as the cell centers don't all lie at the same radius. Nonetheless, you seem to have variations of a degree or more on the cells bordering the exterior, which does seem a bit much. Maybe Wheeler knows if it would be feasible/beneficial to switch to the DiffusionTerm with corrections once a converged solution is obtained with DiffusionTermNoCorrection. > and when the next realease will be available ? When it's ready? Hopefully not too long, but I really couldn't put a date on it.