Hm. Reducing the mesh range (l=50. -> l=30.) does seem to introduce leaking
even when the initial cell volume = 1 (timestep 485). Why would the domain
matter when the BCs are zero-flux?

On Wed, Jun 20, 2012 at 1:36 PM, Jonathan Guyer <[email protected]> wrote:

>
> On Jun 20, 2012, at 3:25 PM, Yun Tao wrote:
>
> > Thanks! Huge help! So, does phi.getCellVolumeAverage() * l act just like
> integration under FiPy then?
>
> Yes.
>
>
> > If so, for 2-D systems, would I simply do phi.getCellVolumeAverage() * l
> * l ?
>
> phi.getCellVolumeAverage() * mesh.getCellVolumes().sum() is what you
> should use in general.
>
>
> _______________________________________________
> fipy mailing list
> [email protected]
> http://www.ctcms.nist.gov/fipy
>   [ NIST internal ONLY: https://email.nist.gov/mailman/listinfo/fipy ]
>



-- 
Graduate Group of Ecology Doctoral Candidate
Department of Environmental Science and Policy
Center for Population Biology
University of California, Davis

Attachment: s-cd1dx.py
Description: Binary data