Hello,

Alex Peshkoff, le Wed 18 May 2011 10:27:32 +0400, a écrit :
> > ../src/jrd/os/posix/isc_ipc.cpp:187:31: error: 'SA_SIGINFO' was not
> > declared in
> >                                                        this scope

Indeed, some systems do not have SA_SIGINFO. I'd suggest the attached
patch to cope with them.

Samuel
--- src/jrd/os/posix/isc_ipc.cpp.original       2011-08-20 16:12:53.342786365 
+0200
+++ src/jrd/os/posix/isc_ipc.cpp        2011-08-20 16:14:54.042717109 +0200
@@ -124,7 +124,11 @@
 static bool isc_signal2(int signal, FPTR_VOID handler, void* arg, ULONG);
 static SIG que_signal(int signal, FPTR_VOID handler, void* arg, int flags, 
bool w_siginfo);
 
+#ifdef SA_SIGINFO
 static void CLIB_ROUTINE signal_action(int number, siginfo_t *siginfo, void 
*context);
+#else
+static void CLIB_ROUTINE signal_action(int number);
+#endif
 
 #ifndef SIG_HOLD
 #define SIG_HOLD       SIG_DFL
@@ -183,20 +187,34 @@
        if (!sig) {
                struct sigaction act, oact;
 
+#ifdef SA_SIGINFO
                act.sa_sigaction = signal_action;
                act.sa_flags = SA_RESTART | SA_SIGINFO;
+#else
+               act.sa_handler = signal_action;
+#endif
                sigemptyset(&act.sa_mask);
                sigaddset(&act.sa_mask, signal_number);
                sigaction(signal_number, &act, &oact);
+#ifdef SA_SIGINFO
                old_sig_w_siginfo = oact.sa_flags & SA_SIGINFO;
+#endif
 
-               if (oact.sa_sigaction != signal_action &&
+               if (
+#ifdef SA_SIGINFO
+                       oact.sa_sigaction != signal_action &&
+#else
+                       oact.sa_handler != signal_action &&
+#endif
                        oact.sa_handler != SIG_DFL &&
                        oact.sa_handler != SIG_HOLD &&
                        oact.sa_handler != SIG_IGN)
                {
-                       que_signal(signal_number, old_sig_w_siginfo ?
+                       que_signal(signal_number,
+#ifdef SA_SIGINFO
+                       old_sig_w_siginfo ?
                                reinterpret_cast<FPTR_VOID>(oact.sa_sigaction) :
+#endif
                                reinterpret_cast<FPTR_VOID>(oact.sa_handler),
                                NULL, SIG_client, old_sig_w_siginfo);
                        rc = true;
@@ -322,6 +340,12 @@
                DEV_REPORT("que_signal: out of memory");
                return NULL;                    /* NOMEM: not handled, too 
difficult */
        }
+#ifndef SA_SIGINFO
+       if (sig_w_siginfo) {
+               DEV_REPORT("SA_SIGINFO not supported");
+               return NULL;
+       }
+#endif
 
 #ifdef DEBUG_GDS_ALLOC
 /* This will only be freed when a signal handler is de-registered
@@ -344,7 +368,11 @@
 }
 
 
+#ifdef SA_SIGINFO
 static void CLIB_ROUTINE signal_action(int number, siginfo_t *siginfo, void 
*context)
+#else
+static void CLIB_ROUTINE signal_action(int number)
+#endif
 {
 /**************************************
  *
@@ -364,11 +392,13 @@
                {
                        if (sig->sig_flags & SIG_client)
                        {
+#ifdef SA_SIGINFO
                                if (sig->sig_w_siginfo)
                                {
                                        (*sig->sig_routine.client3)(number, 
siginfo, context);
                                }
                                else
+#endif
                                {
                                        (*sig->sig_routine.client1)(number);
                                }
------------------------------------------------------------------------------
Special Offer -- Download ArcSight Logger for FREE!
Finally, a world-class log management solution at an even better 
price-free! And you'll get a free "Love Thy Logs" t-shirt when you
download Logger. Secure your free ArcSight Logger TODAY!
http://p.sf.net/sfu/arcsisghtdev2dev
Firebird-Devel mailing list, web interface at 
https://lists.sourceforge.net/lists/listinfo/firebird-devel