VC runtime installer can reboot system prior to installation finishing
----------------------------------------------------------------------

                 Key: CORE-3900
                 URL: http://tracker.firebirdsql.org/browse/CORE-3900
             Project: Firebird Core
          Issue Type: Bug
          Components: Installation
         Environment: Windows 7 fresh installation during first boot process
            Reporter: Brenden Walker
            Priority: Minor


If the VC runtime installer needs to reboot to finish installation it will 
cause the FB installer to reboot the system with no warning (due to /qn passed 
to msiexec) before the FB installer finishes.  This page 
http://desktopengineer.com/windowsinstallererrorcodes notes that msiexec 
returns exit code 3010 if a reboot is needed perhaps running always with 
/norestart and setting internal reboot required flag would be preferable.

The only time we've seen this is with freshly imaged Win 7 machines during the 
first boot process.  

-- 