11.05.2014 10:44, Vlad Khorsun wrote:
It is better to write application to test it. And application should be clever enough to be able to put already read blob_id into parameter instead of creating new blob_id.
I tested with attached application and got this: tx1: blob id = 80:1 tx2: blob id = 80:2 tx1: blob id = 80:3Which seems to be logical, because engine cannot tell whether blob id it has on input comes from current record or other record in other table. Comment in BLB_move confirms that:
// If the source is a permanent blob, then the blob must be copied. // Otherwise find the temporary blob referenced. -- WBR, SD.
b_test.cpp.7z
Description: Binary data
------------------------------------------------------------------------------ Is your legacy SCM system holding you back? Join Perforce May 7 to find out: • 3 signs your SCM is hindering your productivity • Requirements for releasing software faster • Expert tips and advice for migrating your SCM now http://p.sf.net/sfu/perforce