FBSVCMGR does not produce error when we attempt to move database in shutdown
mode and forget to specify timeout (prp_force_shutdown N)
--------------------------------------------------------------------------------------------------------------------------------------
Key: CORE-5270
URL: http://tracker.firebirdsql.org/browse/CORE-5270
Project: Firebird Core
Issue Type: Bug
Components: SVCMGR
Affects Versions: 3.0.0, 4.0 Initial
Reporter: Pavel Zotov
1) C:\MIX\firebird\fb40\gfix -shut single
/3400:C:\MIX\firebird\QA\fbt-repo\tmp\E40.fdb
STDOUT: empty
STDERR: must specify type of shutdown
// OK, expected
2) C:\MIX\firebird\fb40\fbsvcmgr localhost:service_mgr user sysdba password
masterke action_properties dbname C:\MIX\firebird\QA\fbt-repo\tmp\E40.fdb
prp_shutdown_mode prp_sm_single
STDOUT: empty
STDERR: empty!
PS. Fortunately, DB attributes are not changed in the latter case.
--