Hi, 
I'm trying to decode the SWX FAST stream, and in particular an optional ASCII 
string attribute (named RandomisedInterval) with delta operator and no initial 
value (default base value 'Empty String' is used). 
Let suppose we have an undefined dictionary previous value (i.e. the 'Empty 
String' should be used as previous value) and we read from the stream an ASCII 
String Delta made by a Substraction Length = 1 followed by an ASCII String that 
in that case corresponds to the whole RandomisedInterval string "00:02:00".

The problem I'm facing with is quite simple: since I consider the 'Empty 
String' (the default base value) as a string with lenght=0, a Substraction 
Length = 1 (meaning to remove 1 character from the back of base value) makes my 
application to report the error [ERR D7].

I would like to undertand if I'm making a mistake calculating the actual length 
of the 'Empty String' or if the right behaviour is actually to report the 
error. 


Furthermore, since I also consider the string "\0" as it had length=0, I think 
a similar problem could arise in any case I have a dictionary previous value = 
'Empty String' or "\0".

Many thanks in advance.







[You can unsubscribe from this discussion group by sending a message to 
mailto:[email protected]]

--~--~---------~--~----~------------~-------~--~----~
You received this message because you are subscribed to the Google Groups 
"Financial Information eXchange" group.
To post to this group, send email to [email protected]
To unsubscribe from this group, send email to 
[email protected]
For more options, visit this group at 
http://groups.google.com/group/FIX-Protocol?hl=en
-~----------~----~----~----~------~----~------~--~---

Reply via email to