[This message was posted by Nick S of private <[email protected]> to the 
"4.0 Session" discussion forum at http://fixprotocol.org/discuss/12. You can 
reply to it on-line at http://fixprotocol.org/discuss/read/bb15cc49 - PLEASE DO 
NOT REPLY BY MAIL.]

Hi,

I am considering a scenario where FIX Engine A sends Logout message (seq# 20) 
to FIX Engine B (FE_B).

FE_B, is expecting message with seq# 15, so having received Logout message, 
sends a resend request (Begin#=15, End#=0) to FE_A.

FE_A is happy to retransmit all messages starting from seq#15. However, as per 
specs, it is not suppose to retransmit "Logout" message. In this case, FE_B has 
no way to know, when to logout. (FE_B has requested resending of all messages 
starting 15, with no ending defined).

Is it FE_A's responsibility to send Logout explicitly again, or FE_B should 
just count messages 15-19, and then Logout?


Nick