Closing the loop on this one.

The "problem" of not showing the preamble and postamble tones on Olivia is not unique to 3.13CA and greater. This has been around for a long time. It has to do with the size of the audio samples passed from the modem class to waterfall widget. The waterfall drop rate and display is based on receiving blocks of audio that are 512 samples long. Olivia was passing a sample set of 8000 during the pre and post amble periods. Perfectly good set of audio samples, just too big for the way that fldigi's waterfall FFT processes the samples. A very simple fix in the Olivia code and the tones are now perfectly visible on the waterfall. The fix also resolves the waterfall delay previously seen during those intervals.

I will publish a 3.20.0b3 with this and two other fixes to non critical bug reports.

Dave
=================================
Mitch Baum wrote:
Guys,

I just loaded up the 3.20 beta and the is an interesting development - on the waterfall when monitoring TX, the upper and lower "marker tones" are no longer visible. I do hear them being transmitted, but the waterfall freezes during the transition from TXID to standard Olivia (any mode). Sometimes under OS-X the whole waterfall gets locked up. I haven’t been able to reproduce the issue with any regularity, so its still rather random.

I noticed this in 3.13CA, but not in some earlier versions.
I am seeing that on Windows Vista and Linux.

Only associated with Olivia. I will look at Olivia specific changes from BZ to current.

Dave

_______________________________________________
fldigi-alpha mailing list
[email protected]
https://lists.berlios.de/mailman/listinfo/fldigi-alpha

Reply via email to