Greetings,

I just tried C1 with my Yaesu FT-100D, WinXP Pro/SP3, and it works exactly the same as the public release, still exhibiting the bug where the following happens:

* Open Flrig
* Set VFO A to anything
* Set VFO B to, e.g., 14.070 MHz, DIG, 500 Hz filter
* Click on VFO A button - all is good
* Click on VFO B button, it goes to 14.070, DIG, but resets filter to 2400

This also happens with VFO B and VFO A swapped, e.g.,

* Open Flrig
* Set VFO B to anything
* Set VFO A to, e.g., 14.070 MHz, DIG, 500 Hz filter
* Click on VFO B button - all is good
* Click on VFO A button, it goes to 14.070, DIG, but resets filter to 2400

So, either way, when changing VFO the filter setting is not "sticking" as it should.  It's a bug!

73,
-Joe-

Dick wrote:

On Apr 18, 2011, at 11:07 AM, w1hkj wrote:

http://www.w1hkj.com/alpha/flrig/

All of you have indicated a desire to test flrig.  This version represents a significant change from the current public distribution.  Please download, install and test at your convenience.  Report successes and failures.  Include the following:

Transceiver

Kenwood TS-590S

OS (version)

Mac OS X 10.6.7 Snow Leopard

h/w interface

Keyspan USA-28X Serial to USB adaper

Preference file, i.e.
OS X: ~/.flrig/<xcvr>.prefs




What we know works -still work. No S-Meter or Output power reading and it controls NB #1, but not NB #2

Dick AA5VU
_______________________________________________ fldigi-alpha mailing list [email protected] https://lists.berlios.de/mailman/listinfo/fldigi-alpha

-- 
+---------------------------------------------------------------+
| Joseph A. Counsil  [email protected]  Phone:(573) 341-5186 |
| 1310 Woodlawn Drive, Rolla, MO 65401  Amateur Radio: - KØOG - |
+---------------------------------------------------------------+

_______________________________________________
fldigi-alpha mailing list
[email protected]
https://lists.berlios.de/mailman/listinfo/fldigi-alpha

Reply via email to