flent-users <notificati...@github.com> writes:
> Hi Toke,
>
>
>> On Apr 1, 2020, at 12:09, Toke Høiland-Jørgensen <notificati...@github.com>
>> wrote:
>>
>>
>> flent-users <notificati...@github.com> writes:
>>
>> > Hi Toke,
>> >
>> > that sounds great!
>> > Question: Are the marking parameters in decimal? So can I for example
>> > just take the decimal values from
>> > https://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus1000/sw/4_0_4_s_v_1_3/qos/configuration/guide/n1000v_qos/n1000v_qos_6dscpval.html
>> > or related tables?
>>
>> I'd actually suggest you just use the symbolic values (e.g., 'CS0').
>
> Probably decent advise for RFC endorsed named DSCPs, but I want
> to try a all 6bit DSCP variant at one point in time and hence
> need numerical inputs as well.
Right. Well, in that case I think probably the safest is to use
hexadecimal values prefixed with 0x. Netperf seems to want that at
least, and irtt will take both...
>> Flent will make sure to convert them to decimal values for the tools
>> that don't understand the symbolic ones. This is the list of supported
>> symbolic values:
>>
>> https://github.com/tohojo/flent/blob/master/flent/runners.py#L105
>
> Ah, I guess that list could be extended and that you take patches?
Sure.
--
You are receiving this because you commented.
Reply to this email directly or view it on GitHub:
https://github.com/tohojo/flent/issues/203#issuecomment-607186010
_______________________________________________
Flent-users mailing list
Flent-users@flent.org
http://flent.org/mailman/listinfo/flent-users_flent.org