You may find this thread useful:

http://tech.groups.yahoo.com/group/flexcoders/message/120115


--- In [email protected], "Jim Hayes" <[EMAIL PROTECTED]> wrote:
>
> I'm sure I'm missing something here, but It would be good if anyone
> could point out exactly what it is!
> 
> I'm attempting to configure a remoteObject *without* the compiler option
> of    -services \\someServer\Path\WEB-INF\flex\services-config.xml or
> similar 
> 
> I initally thought it would be a question of merely specifying an
> endpoint, so I started off with this in my actionscript class :
> 
> _remoteObj = new RemoteObject();
> _remoteObj.makeObjectsBindable = true;
> _remoteObj.destination = "fluorine";
> _remoteObj.source = "ppRemoteService";
> // add the endpoint, all the code above works fine with the compiler -
> services option
> _remoteObj.endpoint = "http://localhost/ppBackend/Gateway.aspx";;
> 
> Which errors out at runtime with :
> 
> "Cannot assign operations into an RPC Service (endpoint)"
> 
> Yet, if I define the service in my main Application mxml in what looks
> to me like identical parameters , like this :
> 
> <mx:RemoteObject id="testRemoteMxml" 
>                       makeObjectsBindable="true" 
>                       destination="fluorine" 
>                       source="ppRemoteService" 
>       
> endpoint="http://localhost/ppBackend/Gateway.aspx"; />
> 
> then just use  _remoteObj = Application.application.testRemoteMxml into
> my actionScript class (apologies for bad form there)
> 
> it works just fine.
> 
> This is in flexbuilder 3.0 with the default "Flex 3" SDK, I should
> mention.
> 
> So what am I missing? A timing / initialisation error would be my first
> thought, but if so then I can't see quite how.
> 
> I'm probably just being a bit stupid, anyone got any ideas or relevant
> experience?
> 
> Many thanks,
> 
> Jim.
> 
> (p.s. I notice that there is no autocomplete suggestion in flexbuilder
> for remoteObjectInstance.endpoint in actionScript yet it compiles fine.
> This is probably a clue that I'm doing something wrong, I would say. If
> only I knew what it was!)
> 
> ______________________________________________________________________
> This communication is from Primal Pictures Ltd., a company
registered in England and Wales with registration No. 02622298 and
registered office: 4th Floor, Tennyson House, 159-165 Great Portland
Street, London, W1W 5PA, UK. VAT registration No. 648874577.
> 
> This e-mail is confidential and may be privileged. It may be read,
copied and used only by the intended recipient. If you have received
it in error, please contact the sender immediately by return e-mail or
by telephoning +44(0)20 7637 1010. Please then delete the e-mail and
do not disclose its contents to any person.
> This email has been scanned for Primal Pictures by the MessageLabs
Email Security System.
> ______________________________________________________________________
>


Reply via email to