What happens if it is 6 ms/int? 


-Tim

-----Original Message-----
From: [email protected] [mailto:[email protected]] 
On Behalf Of Al
Sent: Monday, February 08, 2010 10:25 AM
To: [email protected]
Subject: [FlexEdge] VAC and ms per int

I recently ran into a problem using PSDR/VAC/WINMOR..  The Winmore two tone 
test produced unstable ( braking up ) output from PSDR and the Flex.. After 
some trial and error, I discovered that the output became stable if I change 
the VAC "Ms per int" from the default of 7 to 8..
This may have something to do with fact that my PSDR sample rate of 48000 
becomes a integer number of samples per int at 8  ( 48000 samples/sec  / 8 Ms 
per int ) = 6000 samples / int ). At 7 it's, 48000/7 = 6857.14....
   ( on the other hand  44100 / 7 = 6300 )

If anyone concurs, I would recommend changing VAC setup recommendation to 8 Ms 
per int.

AL, K0VM