What happens if it is 6 ms/int?
-Tim -----Original Message----- From: [email protected] [mailto:[email protected]] On Behalf Of Al Sent: Monday, February 08, 2010 10:25 AM To: [email protected] Subject: [FlexEdge] VAC and ms per int I recently ran into a problem using PSDR/VAC/WINMOR.. The Winmore two tone test produced unstable ( braking up ) output from PSDR and the Flex.. After some trial and error, I discovered that the output became stable if I change the VAC "Ms per int" from the default of 7 to 8.. This may have something to do with fact that my PSDR sample rate of 48000 becomes a integer number of samples per int at 8 ( 48000 samples/sec / 8 Ms per int ) = 6000 samples / int ). At 7 it's, 48000/7 = 6857.14.... ( on the other hand 44100 / 7 = 6300 ) If anyone concurs, I would recommend changing VAC setup recommendation to 8 Ms per int. AL, K0VM _______________________________________________ Flexedge mailing list [email protected] http://mail.flex-radio.biz/mailman/listinfo/flexedge_flex-radio.biz This is the FlexRadio Systems e-mail Reflector called FlexEdge. It is used for posting topics related to SDR software development and experimentalist who are using alpha and beta versions of the software. _______________________________________________ Flexedge mailing list [email protected] http://mail.flex-radio.biz/mailman/listinfo/flexedge_flex-radio.biz This is the FlexRadio Systems e-mail Reflector called FlexEdge. It is used for posting topics related to SDR software development and experimentalist who are using alpha and beta versions of the software.